    Fire Detection Systems Periodic Maintenance

    Fires may occur due to human errors or system failures. No matter what, a fire can cause loss of life and property. Fire detection systems are efficient mechanisms that minimize or completely prevent these losses. Fire detection through detectors; It detects smoke, soot and temperature rise and gives a warning to the electrical panel. Periodic maintenance of fire detection systems is very important for the efficient operation of the devices. Systems produced with modern technologies can now automatically give a pollution warning. Since accumulated dirt can cause false alarms, it is recommended to perform maintenance on time. Weekly and monthly maintenance is done by the company, while 3, 6 and 12 month maintenance is done by authorized services.

    FIRE DETECTION SYSTEMS
    Read More
    Floor Repeater Terminal – FT2010-A1
    FT2010-A1
    Product Features

    Small floor repeater operation and display panel with large backlit display and plain text reading (6 lines of 40 characters each) for use with the addressable Sinteso FS20 and Cerberus PRO FS720 fire detection systems.

    Responsible personnel at the client’s premises have access to a clearly structured user interface for client-specific plain texts to ensure full localization of events.

    Sections and zones that are operated and visualized using the floor repeater terminal are configurable.

    It is possible to display alarms, pre-alarms, technical messages, faults, isolations.

    With the navigation keys, a list specified on the screen can be navigated.

    Confirmation and reset of events.

    Same event text as fire control panel or fire terminal. Nordic key switch for operating access.

    Power supply via FDnet/C-NET, separate 24 V power supply possible.

    The floor repeater terminal can be operated in loops or stub lines.

    Technicial Specifications
    • Operating voltage DC 12…32 V
    • Supply voltage DC 20...30 V AC 15…18 V (external supply input)
    • Power supply Loop powered, external
    • Current consumption 5 mA @ 24 V (quiescent current, LCD illumination inactive) 45 mA @ 24 V (max. current, LCD illumination active)
    • Cable capacity 0.8...1.5 mm2
    • Communication protocol FDnet/C-NET
    • System compatibility FDnet -> FS20 C-NET -> FS720
    • Protection category IP30
    • Operating temperature '-8…42 °C
    • Storage temperature '-20...+60 °C
    • Relative humidity ≤95 % rel. (no condensation)
    • Color Light grey, ~RAL 7035
    • Dimensions (W x H x D) 282 x 207 x 79 mm
    • Accessories FHA2013-A1 Rear (FT201x flat)
    • Number of addresses 1
    • Standard EN 54-17 , EN 54-18